Find Companies

ONE HOUR FIRE RATED GLASS DOOR

Fire Rated Swing DoorAn equal double leaf insulated glass doorset
COC No.CLS1A 107393 005 Rev. 01
ModelFG-D01
Product Description60 mins Integrity, 60 mins Insulation
Fire Test Report7191230771-MEC20-LC_CR
Fire Test StandardEN 1634-1:2014/A1:2018
Impact Test Report7191220590-MEC19-TWS
Impact Test StandardBS6206:1981

Fire Rated Glass Partition SystemNon-load bearing wall
COC No.CLS1A 107393 001 Rev. 00
ModelFG-FP01
Product Description60 mins Integrity, 60 mins Insulation
Fire Test Report7191234944-MEC20-ILY
Fire Test StandardEN 1364-1:2015
Impact Test Report7191220590-MEC19-TWS
Impact Test StandardBS6206:1981

CONTRAFLAM 60-3
“Multi-Laminated Insulated Fire Rated Glass”

Technical Specifications
Element thickness27mm
Glass size per thickness≤ 1500mm x 2500mm
Weight59 kg/m2
Sound Reduction Rw (EN 140-3)43dB
Light transmission (EN 410)
81%
Light reflection pL (exterior/interior)
10%/10%
U value, w/m2K (EN 673)
4,4
g value
0,65
Energy transmission
56%
Energy reflection
8%/8%